ORIGINAL CONTRIBUTIONS
Outcomes of Robot-Assisted Roux-en-Y Gastric Bypass as a Reoperative Bariatric Procedure
Vivek Bindal & Raquel Gonzalez-Heredia & Enrique Fernando Elli
# Springer Science+Business Media New York 2015
Abstract
Background We evaluate the outcomes of robot-assisted Roux-en-Y gastric bypass (RRYGB) as a reoperative bariatric procedure (RBP).
Methods A retrospective analysis was done from 2007 to 2014, and all the patients who underwent RRYGB as a RBP at a teaching university hospital were included.
Results A total of 32 patients underwent RRYGB as a reop- eration from adjustable gastric band (AGB n=16) or sleeve gastrectomy (SG n = 11) or previous gastric bypass (n = 5). Twenty patients underwent conversion to RRYGB due to weight loss failure, either after AGB (n=13) or SG (n=7). Twelve patients underwent reoperation because of complica- tions of index procedure. Mean preoperative weight was
109.7±29.5 kg, and BMI was 40±10.6 kg/m2. The mean op-
erative time for RRYGB was 226±45.3 min with a blood loss of 20±15.9 ml. Average length of stay was 3 days. In two cases, pin point leaks were detected intraoperatively during check gastroscopy, and they were repaired with sutures. There were no postoperative anastomotic leaks or hemorrhage or gastrojejunostomy strictures. None of the patients required a blood transfusion or reoperation within perioperative period. In the patients who underwent RRYGB for weight loss failure (n=20), the mean excess weight loss (EWL) was 39.2 % at 6 months (n=11), 53.8 % at 1 year (n=13), and 60.7 % at
Conclusions RRYGB is safe and effective to be used as a revisional bariatric procedure. The weight loss outcomes and complication rates compare favorably with the published re- sults of laparoscopic technique, although the small sample size may not be enough to reach definite conclusions.
V. Bindal (*) : R. Gonzalez-Heredia : E. F. Elli
Division of General, Minimally Invasive and Robotic Surgery,
University of Illinois at Chicago, Chicago, USA e-mail: bindal.vivek@gmail.com
Keywords Robot . Revisional . Gastric bypass . Reoperation . Bariatric surgery . Gastric band
Morbid obesity is a chronic disease requiring lifelong treat- ment. Bariatric surgery is currently the most effective and consistent treatment modality for morbidly obese patients to achieve weight loss, decreasing obesity-related comorbidities, and improving overall quality of life and survival [1]. However, there are some patients who do not loose enough weight or have persistent complications after a bariatric pro- cedure [2]. These may be candidates for a reoperative bariatric procedure to address their issues. Due to the rise in number of primary bariatric procedures, surgeons have started to encoun- ter a significant number of these patients.
The commonly performed bariatric procedures in order of increasing complexity are adjustable gastric banding (AGB), sleeve gastrectomy (SG), Roux-en-Y gastric bypass (RYGB), and biliopancreatic diversion with or without duodenal switch (BPD ± DS). The restrictive procedures like AGB and SG have a higher failure rate in terms of weight loss as compared to RYGB and BPD ± DS which are both restrictive and malabsorptive [3]. There may be complications of primary procedures like band erosion, band slippage, severe reflux, stricture, marginal ulceration, internal hernia etc. requiring a reoperation. The weight loss expectations after a revision may not be the same as with the index bariatric procedure.
Reoperations pose significant technical difficulty and chal- lenge to the bariatric surgeons. It carries a higher risk of com- plications, and a possibility that it may have to be done in a staged fashion rather than a single intervention. This is due to the presence of scarring, adhesions and inflammation, which increase the risk of bleeding and anastomotic complications. It also increases the chances of conversion to open from a
minimally invasive procedure. Some of these challenges are related to the limitations of conventional laparoscopy like rig- id instruments, two-dimensional vision, and tremor amplifica- tion. Robotic surgery provides the potential advantages of three-dimensional vision, increased dexterity and precision by downscaling surgeon movements, and obliteration of tremors enabling a fine tissue dissection [4]. It overcomes the restraint of torque on ports from thick abdominal wall and minimizes port site trauma by remote center technology. Selected case series have shown better outcomes with robot- assisted RYGB (RRYGB) as compared to laparoscopic RYGB (LRYGB); however, further studies are required to demonstrate the benefits of robotic surgery vs standard lapa- roscopic techniques [5, 6]. Also, there are limitations of this technique like lack of haptic feedback, need of trained bedside assistant, and added cost.
Independent of the indication, RYGB is the most common- ly performed reoperative procedure [7]. Our division has an extensive experience in robot-assisted bariatric procedures, both primary and reoperations. In this study, we look at our outcomes of RRYGB as a reoperative procedure, performed either after AGB, SG, or RYGB as the index operation.
With an institutional review board approved protocol, the pro- spectively collected database at University of Illinois Medical Center in Chicago was reviewed retrospectively from May 2007 to Feb 2014. A total of 32 patients were included who underwent robot-assisted RYGB as a reoperative bariatric pro- cedure. Patients who underwent a robot-assisted reoperative procedure other than RYGB were excluded, as were those who had a different index procedure apart from AGB, SG, or RYGB. The indications varied from weight loss failure, weight regain, and complications of primary bariatric proce- dure. Informed consent was obtained after explaining all the risks and benefits involved. All patients eligible for a reoper- ation were offered robotic surgery for performing the proce- dure. A preoperative upper gastrointestinal endoscopy or a contrast study was performed in all cases to delineate the anatomy and rule out complications like band erosion, stric- ture, marginal ulceration etc.
The American Society of Metabolic and Bariatric Surgery task force has classified reoperative bariatric procedures into conversion (changing an index procedure to a different type of procedure), corrective (to address complications or incom- plete treatment of a previous bariatric procedure), or reversal (to restore the normal anatomy) [8]. For the purposes of this manuscript, the first operation was considered the index oper- ation, and the second operation was considered the reopera- tion (either corrective or conversion).
Patient demographics, clinical characteristics, obesity-related comorbidities, index operation, indication for reoperation, op- erative parameters, conversions, complications, reoperations (within 30 days of surgery), excess weight loss (EWL), and mortality were recorded and analyzed. Operative time was defined as time between the first skin incision and the last skin closure. Length of hospital stay denoted time between surgical procedure and discharge of the patient. Conversion was con- sidered when there was a need to convert to laparoscopic or open approach in order to complete the procedure. An assess- ment of the percentage EWL was obtained at 6 months, 1 year, and 2 year after reoperation. The ideal body weight was cal- culated equivalent to a BMI of 25 kg/m2, and the EWL was calculated from pre-revision weight. The results of parametric and nonparametric data were expressed as mean±standard deviation (SD) and median (range), respectively. Statistical analysis was done using IBM® SPSS® Statistics software version 19.0. Confidence intervals were set at 95 %.
All the procedures were performed using da Vinci Surgical System (Intuitive Surgical, Sunnyvale, CA)®. We prefer to conduct conversion as a one-stage procedure whenever possi- ble, because it decreases the number of sittings and overall cost. The detailed surgical procedure was dependent on the index operation and the indication for reoperation. The end point in all cases was to create RYGB by either converting previous AGB/SG or correcting previous RYGB. To accom- plish this, patients were placed in 15–20° reverse Trendelenberg position with a urinary catheter in situ. The abdomen was entered with optical trocar in the left upper quadrant and camera port was placed. Overall, five ports were placed including three da Vinci trocars. Nathanson liver re- tractor was placed in epigastrium for liver retraction whenever possible; else the liver was retracted dynamically using the third robotic arm. The patient cart was docked from the head end of the patient. The first step in all cases was dissecting the adhesions. This was preferred to be done using the robot with the help of monopolar hook and ultrasonic scalpel.
Band removal is one of the most important steps in revisional surgery for failed AGB. The gastric band produces a fibrotic ring (capsule) around the stomach, and it has to be meticulously excised, as a misfiring of stapler can occur oth- erwise. A check intraoperative gastroscopy was performed after band removal before proceeding with RYGB. This was important as the revision may have to be deferred to a second stage because of an intraoperative complication such as significant hemorrhage or an inadvertent gastric perforation. In cases of previous SG, adhesiolysis was done and anatomy defined.
Table 1 Indication of converting or correcting index procedure to robot-assisted Roux-en-Y gastric bypass (RYGB)
Indication Index procedure (number of patients with percentage in their subgroup)
Results |
||||
Insufficient weight loss/significant weight regain |
13 (81.3 %) |
7 (63.6 %) |
0 |
The index procedure and indication of reoperation in all 32 |
Band prolapse |
2 (12.5 %) |
0 |
0 |
|
Severe reflux |
0 |
3 (27.3 %) |
0 |
patients underwent conversion to RRYGB due to inadequate |
Intolerance/dysphagia |
1 (6.2 %) |
1 (9.1 %) |
0 |
weight loss or weight regain, either after AGB or SG. Twelve |
Marginal ulcer |
0 |
0 |
4 (80 %) |
patients underwent either correction of RYGB or conversion |
Candy cane with hiatal hernia |
0 |
0 |
1 (20 %) |
from AGB/SG because of complications of index procedure. |
Total |
16 |
11 |
5 |
The patient demographics and clinical data are summarized |
Results |
||||
Insufficient weight loss/significant weight regain |
13 (81.3 %) |
7 (63.6 %) |
0 |
The index procedure and indication of reoperation in all 32 |
Band prolapse |
2 (12.5 %) |
0 |
0 |
|
Severe reflux |
0 |
3 (27.3 %) |
0 |
patients underwent conversion to RRYGB due to inadequate |
Intolerance/dysphagia |
1 (6.2 %) |
1 (9.1 %) |
0 |
weight loss or weight regain, either after AGB or SG. Twelve |
Marginal ulcer |
0 |
0 |
4 (80 %) |
patients underwent either correction of RYGB or conversion |
Candy cane with hiatal hernia |
0 |
0 |
1 (20 %) |
from AGB/SG because of complications of index procedure. |
Total |
16 |
11 |
5 |
The patient demographics and clinical data are summarized |
AGB SG RYGB
an intraoperative esophagogastroscopy was done with air leak test in all the cases.
AGB adjustable gastric band, SG sleeve gastrectomy
A small gastric pouch was created using perigastric tech- nique with 2–3 firings of endoscopic staplers. Jejunum was transected at 50 cm from the ligament of Treitz and 120 cm of Roux limb was measured. Jejunojejunostomy (JJ) was done using a 60-mm stapler, and enterotomy closed using PDS 3-0 running suture. The Roux limb was taken to the gastric pouch in an antecolic antegastric fashion, after dividing the omentum if necessary. A hand-sewn gastrojejunostomy (GJ) in two layers with PDS 3–0 was performed. We used the fourth ro- botic arm from the right side of the patient which decreased the dependence on the assistant and allowed the surgeon to retract by himself.
In cases when corrective procedure was required for a pre- vious RYGB, the gastric pouch, GJ, JJ, and Roux limb were defined. Most of these were done for a marginal ulcer or candy cane. In case of marginal ulcer, the GJ was excised and redone with hand-sewn two-layered technique using PDS 3–0. In case of candy cane, the redundant Roux limb was excised using endoscopic stapler. After the reoperation was complete,
in Table 2. All the patients in the series were females. There was no significant difference in any of demographic parame- ters among various groups.
Table 3 lists the operative parameters and outcomes after surgery. There was no significant difference in the operative time, blood loss, or length of stay between diverse groups. An anastomotic leak at GJ was identified intraoperatively in two patients who underwent conversion from AGB to RYGB. Both the leaks were detected during check endoscopy from the jejunal side of anastomosis and were repaired using PDS 3–0 suture. The patients did well postoperatively. There was no conversion to open, postoperative leak or hemorrhage, GJ stricture, reoperation within 30 days or mortality in the entire series.
Twenty patients who underwent conversion from a restric- tive procedure to RYGB for weight loss failure or weight regain were analyzed separately. Out of those, 13 patients underwent conversion from AGB and 7 patients from SG. There was no significant difference in the two groups in any of demographic parameters, operative time, blood loss, or length of stay. The weight loss outcomes were studied at 6, 12, and 24 months with a percentage follow up of 55, 65, and
Table 2 Patient demographics and preoperative parameters
Total (n=32) |
AGB to RYGB (n=16) |
SG to RYGB (n=11) |
Correction of RYGB (n=5) |
|
Mean age (years) |
43±9.4 |
39.9±10.9 |
45.9±8.3 |
43.6±3.5 |
BMI (kg/m2) |
40±10.6 |
43±6.9 |
40.5±13.3 |
30.3±9.9 |
Weight (kg) |
109±29.5 |
116.7±18.8 |
107.7±38.9 |
88.4±29.6 |
ASA score |
2±0.5 |
2.4±0.5 |
2.5±0.5 |
2.2±0.4 |
No. of patients with HTN |
13 (40.6 %) |
9 (56.2 %) |
4 (36.4 %) |
0 |
(percentage of patients in each subgroup)
No. of patients with T2DM
(percentage of patients in each subgroup)
No. of patients with dyslipidemia (percentage of patients in each subgroup)
10 (31.3 %) 6 (37.5 %) 2 (18.2 %) 2 (40 %)
7 (21.9 %) 5 (31.2 %) 2 (18.2 %) 0
AGB adjustable gastric band, SG sleeve gastrectomy, RYGB Roux-en-Y gastric bypass, BMI body mass index, ASA American Society of Anesthesiol- ogists, T2DM type 2 diabetes mellitus, HTN hypertension
Table 3 Perioperative results and outcomes of reoperation |
Total (n=32) |
AGB to RYGB (n=16) |
SG to RYGB (n=11) |
Correction of RYGB (n=5) |
|
Operative time (min) |
226±45.3 |
230±52 |
221.3±42.6 |
226.4±32.9 |
|
Blood loss (ml) |
20±15.9 |
15.6±14.4 |
23.6±18 |
24±15.2 |
|
Length of stay (days) |
3±2.6 |
3±1.5 |
2.9±0.7 |
6.2±5.8 |
|
Conversion |
0 |
0 |
0 |
0 |
|
Reoperation (within 30 days) of reoperative bariatric procedure Intraoperative detection of anastomotic leak |
0 2 (6.25 %) |
0 2 (12.5 %) |
0 0 |
0 0 |
|
Postoperative detection of anastomotic leak |
0 |
0 |
0 |
0 |
|
Postoperative hemorrhage |
0 |
0 |
0 |
0 |
|
AGB adjustable gastric band, SG |
GJ stricture |
0 |
0 |
0 |
0 |
sleeve gastrectomy, RYGB Roux- |
Mortality |
0 |
0 |
0 |
0 |
Table 3 Perioperative results and outcomes of reoperation |
Total (n=32) |
AGB to RYGB (n=16) |
SG to RYGB (n=11) |
Correction of RYGB (n=5) |
|
Operative time (min) |
226±45.3 |
230±52 |
221.3±42.6 |
226.4±32.9 |
|
Blood loss (ml) |
20±15.9 |
15.6±14.4 |
23.6±18 |
24±15.2 |
|
Length of stay (days) |
3±2.6 |
3±1.5 |
2.9±0.7 |
6.2±5.8 |
|
Conversion |
0 |
0 |
0 |
0 |
|
Reoperation (within 30 days) of reoperative bariatric procedure Intraoperative detection of anastomotic leak |
0 2 (6.25 %) |
0 2 (12.5 %) |
0 0 |
0 0 |
|
Postoperative detection of anastomotic leak |
0 |
0 |
0 |
0 |
|
Postoperative hemorrhage |
0 |
0 |
0 |
0 |
|
AGB adjustable gastric band, SG |
GJ stricture |
0 |
0 |
0 |
0 |
sleeve gastrectomy, RYGB Roux- |
Mortality |
0 |
0 |
0 |
0 |
30 %, respectively. Figure 1 reveals the percentage EWL at these time intervals in various groups.
To the best of our knowledge, there are only two published studies reporting outcomes of robot-assisted reoperative bar- iatric surgery [9, 10]. Our study refers in particular to the outcomes of reoperative robot-assisted RYGB, which has not been addressed adequately.
Most of the published series report that the complication rate of revisional RYGB is higher than primary RYGB [11–13]. A recent systematic review of 15 studies (588 pa- tients) evaluated conversion from AGB to laparoscopic RYGB and reported an overall complication rate (major and minor) of 8.5 % with bleeding and anastomotic leak rates of
1.8 and 0.9 %, respectively. The rate of converting to open
was 2.4 % and the mean incidence of reoperation was 6.5 % [14]. In the light of these results, although our series is small, the fact that it had no postoperative leaks or hemorrhage, no strictures, no conversions to open and no reoperation deserves attention and further evaluation in larger studies. The two cases in which a leak was detected intraoperatively occurred fairly early in the series, and may be attributed to learning curve of reoperative surgery. Interestingly, the two previously published studies on outcomes of robot-assisted revisional RYGB also reported no anastomotic leak or hemorrhage [9, 10]. One of the potential reasons of a low rate of anastomotic complications in RRYGB can be a hand sewn GJ rather than stapled GJ as done in most of the laparoscopic series [15, 16]. This becomes more important in the case of reoperations due to scarring and fibrosis, thus increasing the chances of misfiring of a mechanical stapler, or improper approximation of tissues. An intraoperative check endoscopy is a very useful tool in these cases to detect a leak due to technical reasons on
Fig. 1 Weight loss outcomes after conversion of a restrictive procedure to robot-assisted Roux- en-Y gastric bypass due to weight regain/weight loss failure.
Percentage follow-up at 6 months was 55 %, at 12 months was
65 %, and at 2 years was 30 %. EWL excess weight loss, RYGB Roux-en-Y gastric bypass
80
70
60
50
43.1
40 39.2
32.3
30
55.9
53.8
46.4
70.1
60.7
51.2
Band to RYGB (n=13) Sleeve to RYGB (n=7) Combined (n=20)
20
10
0
0 5 10 15 20 25 30
the table itself. As mentioned, it helped us take care of such leak in two cases, thus avoiding potentially disastrous conse- quences in the postoperative period.
The EWL after revisional RYGB has been demonstrated to be lower than that for primary RYGB in many published stud- ies [13, 17, 18]. A systematic review evaluated conversion of 514 AGB patients to laparoscopic RYGB and reported EWL to be 46.3 % (6–12 months), 57.8 % (12–24 months), and
48.2 % (24–48 months) [19]. In our series, the EWL after conversion of AGB to RRYGB was 43.1 % (6 months),
-
% (12 months), and 70.1 % (24 months). Another article reviewed 6 studies (n=114) evaluating conversion from SG to laparoscopic gastric bypass, and reported EWL of 37 % (6 months), 60 % (12 months), and 48 % (24 months) [20]. In our series, the EWL after conversion from SG to RRYGB was 32.3 % (6 months), 46.4 % (12 months) and 51.2 % (24 months). In both these groups, the weight loss outcomes after revisional RRYGB at our institution seem to be in accor- dance with the published literature, or even better.
The operative times in revisional RYGB cases has been shown to be longer as compared to primary RYGB. For performing a laparoscopic revisional RYGB, Zhang et al. [21] reported mean operative time of 272.5 min (n = 172), while Delko et al. [17] reported it to be 201 min (n = 48). There is only one paper that reports the operative time for a robotic revisional RYGB (353 min, n=11) [10]. The mean operative time in our series, which was performed in a teach- ing hospital with fellows and residents, was 226 min (n=32), which is better than most studies, either laparoscopic or robot- ic. One of the perceived disadvantages of using a robotic sys- tem is a longer operative time. It appears to be a matter of getting over the learning curve for the surgeon as well as the operating room (OR) team, in order to reach the acceptable operative time.
Use of robotic platform in complex cases like reoperative bariatric surgery provides an attractive option, considering the amount of challenge faced by surgeons while performing the- se procedures [22]. However, it should be ventured into only after the surgeon and the OR team have gained sufficient experience with use of robotic platform in performing primary bariatric procedures. This is a guiding principle for any type of reoperative bariatric procedure, whether open, laparoscopic or robotic [8].
Even though it brings in new data, this study has some limitations which deserve comment. First, it is a retrospective review of data already collected. Secondly, it does not com- pare laparoscopic technique to robotic technique. Although a prospective randomized controlled trial may be ideal, but it may not be practically possible, considering the relatively small number of patients requiring reoperation and the influ- ence of patient choice as well as insurance reimbursements on the type of reoperative procedure chosen. Finally, the cost has not been assessed as it was beyond the scope of this
retrospective analysis. There has been a concern about cost every time use of robotic system is considered, as the direct costs are generally higher for the robotic approach in bariatric procedures like RYGB [23, 24]. However, Hagen et al. took into consideration the total costs including the complications and readmissions [16]. They found that cost of robotic RYGB was lower as compared to laparoscopic RYGB when all the factors were counted for. There is also a saving due to decrease in number of laparoscopic staplers used in robotic procedures, by doing a hand sewn anastomosis.
Robot-assisted RYGB is safe and effective as a revisional bariatric procedure in experienced hands. The weight loss out- comes and complication rates compare favorably with the published results of laparoscopic technique, although the small sample size may not be enough to reach definite con- clusions. Using robotic platform may provide subtle advan- tages to the surgeon, enabling him or her to reduce complica- tions and improve the clinical outcomes of this technically complex and challenging procedure.
Conflict of Interest Vivek Bindal declared no conflict of interest.
Raquel Gonzalez-Heredia declared no conflict of interest. Enrique F. Elli declared no conflict of interest.
Statement of Informed Consent Informed consent for surgery was obtained from all individual participants included in the study before they underwent the procedure. As this is a retrospective analysis, formal con- sent is not required, and an exempt application was approved by the Institutional Review Board.
Statement of Human Rights For this type of retrospective study, for- mal consent is not required, and an exempt application was approved by the Institutional Review Board.
-
Sjostrom L, Lindroos AK, Peltonen M, et al. Lifestyle, diabetes, and cardiovascular risk factors 10 years after bariatric surgery. N Engl J Med. 2004;351:2683–93.
-
Courcoulas AP, Christian NJ, Belle SH, et al. Weight change and health outcomes at 3 years after bariatric surgery among individuals with severe obesity. JAMA: J Am Med Assoc. 2013;310:2416–25.
-
Kellogg TA. Revisional bariatric surgery. Surg Clin N Am. 2011;91: 1353–71.
-
Bindal V, Bhatia P, Kalhan S, et al. Robot-assisted excision of a large retroperitoneal schwannoma. JSLS : J Soc Laparoendosc Surg Soc Laparoendosc Surg. 2014;18:150–4.
-
Wilson EB, Sudan R. The evolution of robotic bariatric surgery. World J Surg. 2013;37:2756–60.
-
Fourman MM, Saber AA. Robotic bariatric surgery: a systematic review. Surg Obes Relat Dis : Off J Am Soc Bariat Surg. 2012;8: 483–8.
-
Sudan R, Nguyen NT, Hutter MM, et al. Morbidity, mortality, and weight loss outcomes after reoperative bariatric surgery in the USA. Journal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract. 2015;19(1):171–9.
-
Brethauer SA, Kothari S, Sudan R, et al. Systematic review on reoperative bariatric surgery: American Society for Metabolic and Bariatric Surgery Revision Task Force. Surgery for obesity and relat- ed diseases: official journal of the American Society for Bariatric Surgery 2014.
-
Snyder B, Wilson T, Woodruff V, et al. Robotically assisted revision of bariatric surgeries is safe and effective to achieve further weight loss. World J Surg. 2013;37:2569–73.
-
Buchs NC, Pugin F, Azagury DE, et al. Robotic revisional bariatric surgery: a comparative study with laparoscopic and open surgery. Int J Med Robot Comput Assist Aurgery : MRCAS. 2014;10:213–7.
-
Topart P, Becouarn G, Ritz P. One-year weight loss after primary or revisional Roux-en-Y gastric bypass for failed adjustable gastric banding. Surg Obes Relat Dis : Off J Am Soc Bariat Surg. 2009;5: 459–62.
-
Hallowell PT, Stellato TA, Yao DA, et al. Should bariatric revisional surgery be avoided secondary to increased morbidity and mortality? Am J Surg. 2009;197:391–6.
-
Mor A, Keenan E, Portenier D, et al. Case-matched analysis compar- ing outcomes of revisional versus primary laparoscopic Roux-en-Y gastric bypass. Surg Endosc. 2013;27:548–52.
-
Coblijn UK, Verveld CJ, van Wagensveld BA, et al. Laparoscopic Roux-en-Y gastric bypass or laparoscopic sleeve gastrectomy as revisional procedure after adjustable gastric band—a systematic re- view. Obes Surg. 2013;23:1899–914.
-
Buchs NC, Morel P, Azagury DE, et al. Laparoscopic versus robotic Roux-en-Y gastric bypass: lessons and long-term follow-up learned
from a large prospective monocentric study. Obes Surg. 2014;24(12): 2031–9.
-
Hagen ME, Pugin F, Chassot G, et al. Reducing cost of surgery by avoiding complications: the model of robotic Roux-en-Y gastric by- pass. Obes Surg. 2012;22:52–61.
-
Delko T, Kostler T, Peev M, et al. Revisional versus primary Roux- en-Y gastric bypass: a case-matched analysis. Surg Endosc. 2014;28: 552–8.
-
Jennings NA, Boyle M, Mahawar K, et al. Revisional laparoscopic Roux-en-Y gastric bypass following failed laparoscopic adjustable gastric banding. Obes Surg. 2013;23:947–52.
-
Elnahas A, Graybiel K, Farrokhyar F, et al. Revisional surgery after failed laparoscopic adjustable gastric banding: a systematic review. Surg Endosc. 2013;27:740–5.
-
Cheung D, Switzer NJ, Gill RS, et al. Revisional bariatric surgery following failed primary laparoscopic sleeve gastrectomy: a system- atic review. Obes Surg. 2014;24:1757–63.
-
Zhang L, Tan WH, Chang R, et al. Perioperative risk and complica- tions of revisional bariatric surgery compared to primary Roux-en-Y gastric bypass. Surg. Endosc. 2014. doi:10.1007/s00464-014-3848- 4.
-
Vilallonga R, Fort JM, Caubet E, et al. Robotic sleeve gastrectomy versus laparoscopic sleeve gastrectomy: a comparative study with 200 patients. Obes Surg. 2013;23:1501–7.
-
Hubens G, Balliu L, Ruppert M, et al. Roux-en-Y gastric bypass procedure performed with the da Vinci robot system: is it worth it? Surg Endosc. 2008;22:1690–6.
-
Scozzari G, Rebecchi F, Millo P, et al. Robot-assisted gastrojejunal anastomosis does not improve the results of the laparoscopic Roux- en-Y gastric bypass. Surg Endosc. 2011;25:597–603.
-